Menu
Your Cart

RX3000 Water Level Sensor Module

RX3000 Water Level Sensor Module
RX3000 Water Level Sensor Module
RX3000 Water Level Sensor Module
New
RX3000 Water Level Sensor Module
RX3000 Water Level Sensor Module
RX3000 Water Level Sensor Module
RX3000 Water Level Sensor Module
170.80€
Ex Tax:140.00€
  • Model: RXMOD-W1
  • MPN: RXMOD-W1

Overview

​The RX3000 Water Level Sensor Module (RXMOD-W1) offers users the ability to monitor water level, pressure, and temperature, as well as barometric pressure, with the HOBO RX3000 Remote Monitoring Station.  It is configured through HOBOlink, Onset’s cloud-based software. For water level applications, a HOBO RX3000 station, water level sensor cable (CABLE-RWLMOD-XXX), and water level sensor (MX2001-0X-S or MX2001-0X-Ti-S) are required.

 MX2001RX2103/4RX3000
CommunicationsBluetooth Low EnergyCellularEthernet, WiFi, Cellular
Logger Dimensions2.54 cm (1.0 in.) diameter,
28.9 cm (11.4 in.) length
19.95 x 13.68 x 7.49 cm
(7.85 x 5.39 x 2.95 in.)
18.6 x 18.1 x 11.8 cm
(7.3 x 7.1 x 4.7 in.)
Smart Sensor Ports-510
Module PortsNone2*
On-Board Barometric SensorYesWith required Water Level Module (RXMOD-W1)
Water Level Sensor
(MX2001-S/-Ti)
IncludedPurchased separately
Cable Price$70 + $4/m
Logger Price$595
Includes Water Level Sensor
Starting at 640/700
Needs Water Level Sensor
Starting at $899**
Needs Water Level Sensor & Module
*   The RX3000 can only include one Water Level Module/Sensor combination. If your application requires multiple water level sensors, an Analog Module and third party water level sensors with 4-20 mA output are required.
**  Further accessories required for monitoring water level


Highlighted Features 
  • Integrated barometric pressure sensor
  • Plug-and-play remote water level and flow monitoring

In what environment does this accessory operate?

This accessory operates in outdoor and water environments.


What measurements does this accessory support?

The RXMOD-W1 accessory supports the following measurements: Barometric Pressure, Differential Pressure, Remote Water Level Monitoring, Water Flow, Water Level and Water Temperature

Barometric Pressure
Accuracy <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">±0.2 kPa (±0.029 psi) over full temperature range at fixed pressure; maximum error ±0.5% FS</span><br></p>
Operation Range <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">66 to 107 kPa (9.57 to 15.52 psia)</span><br></p>
Resolution <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;0.01&nbsp;kPa (0.0015&nbsp;psi)</span><br></p>
Response Time <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;1 second at a stable temperature</span><br></p>
Stability (Drift) <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;0.01 kPa (0.0015 psi) per year</span><br></p>
Temperature Calibrated Range <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">-20 to 50°C (-4 to 122°C)</span><br></p>
Water Level Accuracy <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Typical error: ±0.075% FS, 0.3 cm (0.01 ft) water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Maximum error: ±0.15% FS, 0.6 cm (0.02 ft) water</span><br></p>
Pressure (Abs.) & Water Level MX2001-01-S and MX2001-01-Ti-S
Burst Pressure <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">310 kPa (45 psia) or 18 m (60 ft) depth</span><br></p>
Factory Calibrated Range <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">69 to 207 kPa (10 to 30 psia), 0 to 40C (32 to 104F)</span><br></p>
Operation Range <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude</span><br></p>
Pressure Response Time (90%) <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;1 second at a stable temperature</span><br></p>
Raw Pressure Accuracy <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0.3% FS, 0.62 kPa (0.09 psi) maximum error</span><br></p>
Resolution <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water</span><br></p>
Water Level Accuracy <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Typical error: 0.05% FS, 0.5 cm (0.015 ft) water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Maximum error: 0.1% FS, 1.0 cm (0.03 ft) water</span><br></p>
Pressure (Abs.) and Water Level MX2001-04-S and MX2001-04-Ti-S
Burst Pressure <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">310 kPa (45 psia) or 18 m (60 ft) depth</span><br></p>
Factory Calibrated Range <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">69 to 145 kPa (10 to 21 psia), 0 to 40C (32 to 104F)</span><br></p>
Operation Range <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m (0 to 23 ft) of water at 3,000 m (10,000 ft) of altitude</span><br></p>
Pressure Response Time (90%) <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;1 second at a stable temperature</span><br></p>
Raw Pressure Accuracy <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0.3% FS, 0.43 kPa (0.063 psi) maximum error</span><br></p>
Resolution <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;0.014 kPa (0.002 psi), 0.14 cm (0.005 ft) water</span><br></p>
Water Level Accuracy <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Typical error: 0.075% FS, 0.3 cm (0.01 ft) water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Maximum error: 0.15% FS, 0.6 cm (0.02 ft) water</span><br></p>
Pressure (Absolute) and Water Level Measurements MX2001-02-S
Burst Pressure <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">500 kPa (72.5 psia) or 40.8 m (134 ft) depth</span><br></p>
Factory Calibrated Range <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">69 to 400 kPa (10 to 58 psia), 0 to 40C (32 to 104F)</span><br></p>
Operation Range <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea level, or 0 to 33.6 m (0 to 111 ft) of water at&nbsp;</span><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">3,000 m (10,000 ft) of altitude</span><br></p>
Pressure Response Time (90%) <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;1 second at a stable temperature</span><br></p>
Raw Pressure Accuracy <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0.3% FS, 1.20 kPa (0.17 psi) maximum error</span><br></p>
Resolution <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;0.04 kPa (0.006 psi), 0.41 cm (0.013 ft) water</span><br></p>
Water Level Accuracy <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Typical error: 0.05% FS, 1.5 cm (0.05 ft) water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Maximum error: 0.1% FS, 3.0 cm (0.1 ft) water</span><br></p>
Pressure (Absolute) and Water Level Measurements MX2001-03-S
Burst Pressure <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">1,200 kPa (174 psia) or 112 m (368 ft) depth</span><br></p>
Factory Calibrated Range <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">69 to 850 kPa (10 to 123.3 psia), 0 to 40C (32 to 104F)</span><br></p>
Operation Range <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0 to 850 kPa (0 to 123.3 psia); approximately 0 to 76.5 m (0 to 251 ft) of water depth at sea level, or 0 to 79.5 m (0 to 262 ft) of water at 3,000 m (10,000 ft) of altitude</span><br></p>
Pressure Response Time (90%) <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;1 second at a stable temperature</span><br></p>
Raw Pressure Accuracy <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0.3% FS, 2.55 kPa (0.37 psi) maximum error</span><br></p>
Resolution <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">&lt;0.085 kPa (0.012 psi), 0.87 cm (0.028 ft) water</span><br></p>
Water Level Accuracy <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Typical error: 0.05% FS, 3.8 cm (0.125 ft) water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Maximum error: 0.1% FS, 7.6 cm (0.25 ft) water</span><br></p>
Water Level Sensor and Cable
Dimensions <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Sensor (MX2001-0x-S and MX2001-0x-Ti-S): 2.54 cm (1.0 inches) diameter, 9.91 cm (3.9 inches) length</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Cable (CABLE-RWL-xxx): 0.47 cm ±0.03 (0.185 inches ±0.01) diameter, 0.2 to 400 m (0.65 to 1,312 ft) length</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><strong style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Note:&nbsp;</strong><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">The length of the water level logger cable can vary -0% to +3% +10 cm (3.9 inches) from the length ordered.</span><br></p>
Materials <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Stainless sensor (MX2001-0x-S): Acetal housing, Viton and Buna-N O-rings, ceramic sensor in stainless steel end cap</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Titanium sensor (MX2001-0x-Ti-S): Acetal housing, Viton and Buna-N O-rings, ceramic sensor in Titanium end cap</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Cable (CABLE-RWL-XXX): Polycarbonate end cap, PVC end cap, polycarbonate collar nut, Viton O-rings, polyurethane jacket</span><br></p>
Specifications
Weight <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Stainless sensor (MX2001-0x-S): Approximately 106 g (3.74 oz) in air; approximately 53.9 g (1.9 oz) in fresh water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Titanium sensor (MX2001-0x-Ti-S): Approximately 80 g (2.83 oz) in air; approximately 37 g (1.3 oz) in fresh water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Cable (CABLE-RWL-XXX): 39 g (1.38 oz) per 1 meter (3.28 ft)</span><br></p>