Menu
Your Cart

RX3000 Water Level Sensor Module

RX3000 Water Level Sensor Module
RX3000 Water Level Sensor Module
RX3000 Water Level Sensor Module
New
RX3000 Water Level Sensor Module
RX3000 Water Level Sensor Module
RX3000 Water Level Sensor Module
RX3000 Water Level Sensor Module
201.30€
Ex Tax:165.00€
  • Model: RXMOD-W1
  • MPN: RXMOD-W1

Overview

​The RX3000 Water Level Sensor Module (RXMOD-W1) offers users the ability to monitor water level, pressure, and temperature, as well as barometric pressure, with the HOBO RX3000 Remote Monitoring Station.  It is configured through HOBOlink, Onset’s cloud-based software. For water level applications, a HOBO RX3000 station, water level sensor cable (CABLE-RWLMOD-XXX), and water level sensor (MX2001-0X-S or MX2001-0X-Ti-S) are required.

 MX2001RX2103/4RX3000
CommunicationsBluetooth Low EnergyCellularEthernet, WiFi, Cellular
Logger Dimensions2.54 cm (1.0 in.) diameter,
28.9 cm (11.4 in.) length
19.95 x 13.68 x 7.49 cm
(7.85 x 5.39 x 2.95 in.)
18.6 x 18.1 x 11.8 cm
(7.3 x 7.1 x 4.7 in.)
Smart Sensor Ports-510
Module PortsNone2*
On-Board Barometric SensorYesWith required Water Level Module (RXMOD-W1)
Water Level Sensor
(MX2001-S/-Ti)
IncludedPurchased separately
Cable Price$70 + $4/m
Logger Price$595
Includes Water Level Sensor
Starting at 640/700
Needs Water Level Sensor
Starting at $899**
Needs Water Level Sensor & Module
*   The RX3000 can only include one Water Level Module/Sensor combination. If your application requires multiple water level sensors, an Analog Module and third party water level sensors with 4-20 mA output are required.
**  Further accessories required for monitoring water level


Highlighted Features 
  • Integrated barometric pressure sensor
  • Plug-and-play remote water level and flow monitoring

In what environment does this accessory operate?

This accessory operates in outdoor and water environments.


What measurements does this accessory support?

The RXMOD-W1 accessory supports the following measurements: Barometric Pressure, Differential Pressure, Remote Water Level Monitoring, Water Flow, Water Level and Water Temperature

Barometric Pressure
Accuracy

±0.2 kPa (±0.029 psi) over full temperature range at fixed pressure; maximum error ±0.5% FS

Operation Range

66 to 107 kPa (9.57 to 15.52 psia)

Resolution

<0.01 kPa (0.0015 psi)

Response Time

<1 second at a stable temperature

Stability (Drift)

<0.01 kPa (0.0015 psi) per year

Temperature Calibrated Range

-20 to 50°C (-4 to 122°C)

Water Level Accuracy

Typical error: ±0.075% FS, 0.3 cm (0.01 ft) water
Maximum error: ±0.15% FS, 0.6 cm (0.02 ft) water

Pressure (Abs.) & Water Level MX2001-01-S and MX2001-01-Ti-S
Burst Pressure

310 kPa (45 psia) or 18 m (60 ft) depth

Factory Calibrated Range

69 to 207 kPa (10 to 30 psia), 0 to 40C (32 to 104F)

Operation Range

0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude

Pressure Response Time (90%)

<1 second at a stable temperature

Raw Pressure Accuracy

0.3% FS, 0.62 kPa (0.09 psi) maximum error

Resolution

<0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water

Water Level Accuracy

Typical error: 0.05% FS, 0.5 cm (0.015 ft) water
Maximum error: 0.1% FS, 1.0 cm (0.03 ft) water

Pressure (Abs.) and Water Level MX2001-04-S and MX2001-04-Ti-S
Burst Pressure

310 kPa (45 psia) or 18 m (60 ft) depth

Factory Calibrated Range

69 to 145 kPa (10 to 21 psia), 0 to 40C (32 to 104F)

Operation Range

0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m (0 to 23 ft) of water at 3,000 m (10,000 ft) of altitude

Pressure Response Time (90%)

<1 second at a stable temperature

Raw Pressure Accuracy

0.3% FS, 0.43 kPa (0.063 psi) maximum error

Resolution

<0.014 kPa (0.002 psi), 0.14 cm (0.005 ft) water

Water Level Accuracy

Typical error: 0.075% FS, 0.3 cm (0.01 ft) water
Maximum error: 0.15% FS, 0.6 cm (0.02 ft) water

Pressure (Absolute) and Water Level Measurements MX2001-02-S
Burst Pressure

500 kPa (72.5 psia) or 40.8 m (134 ft) depth

Factory Calibrated Range

69 to 400 kPa (10 to 58 psia), 0 to 40C (32 to 104F)

Operation Range

0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea level, or 0 to 33.6 m (0 to 111 ft) of water at 3,000 m (10,000 ft) of altitude

Pressure Response Time (90%)

<1 second at a stable temperature

Raw Pressure Accuracy

0.3% FS, 1.20 kPa (0.17 psi) maximum error

Resolution

<0.04 kPa (0.006 psi), 0.41 cm (0.013 ft) water

Water Level Accuracy

Typical error: 0.05% FS, 1.5 cm (0.05 ft) water
Maximum error: 0.1% FS, 3.0 cm (0.1 ft) water

Pressure (Absolute) and Water Level Measurements MX2001-03-S
Burst Pressure

1,200 kPa (174 psia) or 112 m (368 ft) depth

Factory Calibrated Range

69 to 850 kPa (10 to 123.3 psia), 0 to 40C (32 to 104F)

Operation Range

0 to 850 kPa (0 to 123.3 psia); approximately 0 to 76.5 m (0 to 251 ft) of water depth at sea level, or 0 to 79.5 m (0 to 262 ft) of water at 3,000 m (10,000 ft) of altitude

Pressure Response Time (90%)

<1 second at a stable temperature

Raw Pressure Accuracy

0.3% FS, 2.55 kPa (0.37 psi) maximum error

Resolution

<0.085 kPa (0.012 psi), 0.87 cm (0.028 ft) water

Water Level Accuracy

Typical error: 0.05% FS, 3.8 cm (0.125 ft) water
Maximum error: 0.1% FS, 7.6 cm (0.25 ft) water

Water Level Sensor and Cable
Dimensions

Sensor (MX2001-0x-S and MX2001-0x-Ti-S): 2.54 cm (1.0 inches) diameter, 9.91 cm (3.9 inches) length
Cable (CABLE-RWL-xxx): 0.47 cm ±0.03 (0.185 inches ±0.01) diameter, 0.2 to 400 m (0.65 to 1,312 ft) length
Note: The length of the water level logger cable can vary -0% to +3% +10 cm (3.9 inches) from the length ordered.

Materials

Stainless sensor (MX2001-0x-S): Acetal housing, Viton and Buna-N O-rings, ceramic sensor in stainless steel end cap
Titanium sensor (MX2001-0x-Ti-S): Acetal housing, Viton and Buna-N O-rings, ceramic sensor in Titanium end cap
Cable (CABLE-RWL-XXX): Polycarbonate end cap, PVC end cap, polycarbonate collar nut, Viton O-rings, polyurethane jacket

Specifications
Weight

Stainless sensor (MX2001-0x-S): Approximately 106 g (3.74 oz) in air; approximately 53.9 g (1.9 oz) in fresh water
Titanium sensor (MX2001-0x-Ti-S): Approximately 80 g (2.83 oz) in air; approximately 37 g (1.3 oz) in fresh water
Cable (CABLE-RWL-XXX): 39 g (1.38 oz) per 1 meter (3.28 ft)