The RX3000 Water Level Sensor Module (RXMOD-W1) offers users the ability to monitor water level, pressure, and temperature, as well as barometric pressure, with the HOBO RX3000 Remote Monitoring Station. It is configured through HOBOlink, Onset’s cloud-based software. For water level applications, a HOBO RX3000 station, water level sensor cable (CABLE-RWLMOD-XXX), and water level sensor (MX2001-0X-S or MX2001-0X-Ti-S) are required.
MX2001 | RX2103/4 | RX3000 | |
---|---|---|---|
Communications | Bluetooth Low Energy | Cellular | Ethernet, WiFi, Cellular |
Logger Dimensions | 2.54 cm (1.0 in.) diameter, 28.9 cm (11.4 in.) length | 19.95 x 13.68 x 7.49 cm (7.85 x 5.39 x 2.95 in.) | 18.6 x 18.1 x 11.8 cm (7.3 x 7.1 x 4.7 in.) |
Smart Sensor Ports | - | 5 | 10 |
Module Ports | None | 2* | |
On-Board Barometric Sensor | Yes | With required Water Level Module (RXMOD-W1) | |
Water Level Sensor (MX2001-S/-Ti) | Included | Purchased separately | |
Cable Price | $70 + $4/m | ||
Logger Price | $595 Includes Water Level Sensor | Starting at 640/700 Needs Water Level Sensor | Starting at $899** Needs Water Level Sensor & Module |
* The RX3000 can only include one Water Level Module/Sensor combination. If your application requires multiple water level sensors, an Analog Module and third party water level sensors with 4-20 mA output are required.
** Further accessories required for monitoring water level
Highlighted Features
- Integrated barometric pressure sensor
- Plug-and-play remote water level and flow monitoring
In what environment does this accessory operate?
This accessory operates in outdoor and water environments.
What measurements does this accessory support?
The RXMOD-W1 accessory supports the following measurements: Barometric Pressure, Differential Pressure, Remote Water Level Monitoring, Water Flow, Water Level and Water Temperature
Barometric Pressure | |
Accuracy | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">±0.2 kPa (±0.029 psi) over full temperature range at fixed pressure; maximum error ±0.5% FS</span><br></p> |
Operation Range | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">66 to 107 kPa (9.57 to 15.52 psia)</span><br></p> |
Resolution | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><0.01 kPa (0.0015 psi)</span><br></p> |
Response Time | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><1 second at a stable temperature</span><br></p> |
Stability (Drift) | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><0.01 kPa (0.0015 psi) per year</span><br></p> |
Temperature Calibrated Range | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">-20 to 50°C (-4 to 122°C)</span><br></p> |
Water Level Accuracy | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Typical error: ±0.075% FS, 0.3 cm (0.01 ft) water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Maximum error: ±0.15% FS, 0.6 cm (0.02 ft) water</span><br></p> |
Pressure (Abs.) & Water Level MX2001-01-S and MX2001-01-Ti-S | |
Burst Pressure | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">310 kPa (45 psia) or 18 m (60 ft) depth</span><br></p> |
Factory Calibrated Range | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">69 to 207 kPa (10 to 30 psia), 0 to 40C (32 to 104F)</span><br></p> |
Operation Range | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude</span><br></p> |
Pressure Response Time (90%) | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><1 second at a stable temperature</span><br></p> |
Raw Pressure Accuracy | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0.3% FS, 0.62 kPa (0.09 psi) maximum error</span><br></p> |
Resolution | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water</span><br></p> |
Water Level Accuracy | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Typical error: 0.05% FS, 0.5 cm (0.015 ft) water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Maximum error: 0.1% FS, 1.0 cm (0.03 ft) water</span><br></p> |
Pressure (Abs.) and Water Level MX2001-04-S and MX2001-04-Ti-S | |
Burst Pressure | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">310 kPa (45 psia) or 18 m (60 ft) depth</span><br></p> |
Factory Calibrated Range | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">69 to 145 kPa (10 to 21 psia), 0 to 40C (32 to 104F)</span><br></p> |
Operation Range | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m (0 to 23 ft) of water at 3,000 m (10,000 ft) of altitude</span><br></p> |
Pressure Response Time (90%) | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><1 second at a stable temperature</span><br></p> |
Raw Pressure Accuracy | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0.3% FS, 0.43 kPa (0.063 psi) maximum error</span><br></p> |
Resolution | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><0.014 kPa (0.002 psi), 0.14 cm (0.005 ft) water</span><br></p> |
Water Level Accuracy | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Typical error: 0.075% FS, 0.3 cm (0.01 ft) water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Maximum error: 0.15% FS, 0.6 cm (0.02 ft) water</span><br></p> |
Pressure (Absolute) and Water Level Measurements MX2001-02-S | |
Burst Pressure | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">500 kPa (72.5 psia) or 40.8 m (134 ft) depth</span><br></p> |
Factory Calibrated Range | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">69 to 400 kPa (10 to 58 psia), 0 to 40C (32 to 104F)</span><br></p> |
Operation Range | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea level, or 0 to 33.6 m (0 to 111 ft) of water at </span><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">3,000 m (10,000 ft) of altitude</span><br></p> |
Pressure Response Time (90%) | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><1 second at a stable temperature</span><br></p> |
Raw Pressure Accuracy | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0.3% FS, 1.20 kPa (0.17 psi) maximum error</span><br></p> |
Resolution | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><0.04 kPa (0.006 psi), 0.41 cm (0.013 ft) water</span><br></p> |
Water Level Accuracy | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Typical error: 0.05% FS, 1.5 cm (0.05 ft) water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Maximum error: 0.1% FS, 3.0 cm (0.1 ft) water</span><br></p> |
Pressure (Absolute) and Water Level Measurements MX2001-03-S | |
Burst Pressure | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">1,200 kPa (174 psia) or 112 m (368 ft) depth</span><br></p> |
Factory Calibrated Range | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">69 to 850 kPa (10 to 123.3 psia), 0 to 40C (32 to 104F)</span><br></p> |
Operation Range | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0 to 850 kPa (0 to 123.3 psia); approximately 0 to 76.5 m (0 to 251 ft) of water depth at sea level, or 0 to 79.5 m (0 to 262 ft) of water at 3,000 m (10,000 ft) of altitude</span><br></p> |
Pressure Response Time (90%) | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><1 second at a stable temperature</span><br></p> |
Raw Pressure Accuracy | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">0.3% FS, 2.55 kPa (0.37 psi) maximum error</span><br></p> |
Resolution | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><0.085 kPa (0.012 psi), 0.87 cm (0.028 ft) water</span><br></p> |
Water Level Accuracy | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Typical error: 0.05% FS, 3.8 cm (0.125 ft) water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Maximum error: 0.1% FS, 7.6 cm (0.25 ft) water</span><br></p> |
Water Level Sensor and Cable | |
Dimensions | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Sensor (MX2001-0x-S and MX2001-0x-Ti-S): 2.54 cm (1.0 inches) diameter, 9.91 cm (3.9 inches) length</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Cable (CABLE-RWL-xxx): 0.47 cm ±0.03 (0.185 inches ±0.01) diameter, 0.2 to 400 m (0.65 to 1,312 ft) length</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><strong style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Note: </strong><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">The length of the water level logger cable can vary -0% to +3% +10 cm (3.9 inches) from the length ordered.</span><br></p> |
Materials | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Stainless sensor (MX2001-0x-S): Acetal housing, Viton and Buna-N O-rings, ceramic sensor in stainless steel end cap</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Titanium sensor (MX2001-0x-Ti-S): Acetal housing, Viton and Buna-N O-rings, ceramic sensor in Titanium end cap</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Cable (CABLE-RWL-XXX): Polycarbonate end cap, PVC end cap, polycarbonate collar nut, Viton O-rings, polyurethane jacket</span><br></p> |
Specifications | |
Weight | <p><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Stainless sensor (MX2001-0x-S): Approximately 106 g (3.74 oz) in air; approximately 53.9 g (1.9 oz) in fresh water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Titanium sensor (MX2001-0x-Ti-S): Approximately 80 g (2.83 oz) in air; approximately 37 g (1.3 oz) in fresh water</span><br style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;"><span style="font-family: Arial, Helvetica, sans-serif; font-size: 13.3333px;">Cable (CABLE-RWL-XXX): 39 g (1.38 oz) per 1 meter (3.28 ft)</span><br></p> |