HOBO MX2001 Bluetooth Low Energy Water Level Data Logger
























- Model: HOBO MX2001 Water Level
- MPN: MX2001
Available Options
The HOBO® MX2001 is the industry’s first water level data logger designed for convenient wireless setup and download from mobile devices via Bluetooth Low Energy. The logger dramatically simplifies and lowers the cost of field data collection by providing wireless access to high-accuracy water level and temperature measurements right from a mobile phone or tablet. The MX2001 logger consists of a top-end unit and a water level sensor which are sold as a set, plus a direct read cable to connect them. Cables can be ordered in lengths from 0.2 to 500 m for deployment in a wide range of wells.
Highlighted Features
- Wireless data offload to mobile devices using Bluetooth Low Energy
- Direct read cable connects sensor to top-end logger/transmitter
- The cable includes Kevlar strength member
- Cables are interchangeable so loggers are easy to redeploy in future applications
- The logger and sensor add 0.39 meters to the length of the cable
- Cable length can vary up to 3% from the length ordered
- The 1, 5, 10, 15, 30 and 60 meter cable lengths are in stock; custom cable lengths have a 2 to 4 week lead time
- Integrated barometric pressure sensor enables direct water level readout
- Reference water level can be entered at the start of the deployment
- Use HOBOmobile for setup, data viewing and data sharing
- Powered by two user-replaceable AA batteries in the top-end unit
- Several logging modes: normal, multi-rate logging and event-triggered burst-logging
- Durable ceramic sensor
- Available with stainless steel or titanium sensor ends
- 3-point NIST-traceable calibration certificate included for the water pressure sensor
In what environment does this data logger operate?
This data logger operates in outdoor and underwater environments.
What measurements does this data logger support?
The MX2001 data logger supports the following measurements: Absolute Pressure, Barometric Pressure, Differential Pressure, Temperature, Water Level and Water Temperature.
Specifications | |
Barometric Pressure (MX2001-TOP) | <p><br></p><table class="table table-bordered"><tbody><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Operation and Calibrated Range</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">66 to 107 kPa (9.57 to 15.52 psia); -20° to 50°C (-4° to 122°F)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Accuracy</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">±0.2 kPa (±0.029 psi) over full temperature range at fixed pressure; maximum error ±0.5% FS</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Water Level Accuracy*</strong><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Typical error: ±0.075% FS, 0.3 cm (0.01 ft) water</span><br style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Maximum error: ±0.15% FS, 0.6 cm (0.02 ft) water</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">*</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Water Level Accuracy: With accurate reference water level measurement, known water density, and a stable temperature environment. System Water Level Accuracy equals the sum of the Barometric Water Level Accuracy plus the selected sensor end Water Level Accuracy.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span><br></p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Resolution</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">0.01 kPa (0.0015 psi)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Response Time</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">1 second at stable temperature</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Stability (Drift)</strong></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">0.01 kPa per year</span><br></td></tr></tbody></table><p><br></p> |
Logger | <p><br></p><table class="table table-bordered"><tbody><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Operation Range</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">-20° to 50°C (-4° to 122°F)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Radio Power</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">1 mW (0 dBm)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Transmission Range</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Approximately 30.5 m (100 ft) line-of-sight</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Wireless Data Standard</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Bluetooth Low Energy (Bluetooth Smart)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Logging Rate</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">1 second to 18 hours</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Logging Modes</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Fixed interval, multiple intervals with up to 8 user-defined logging intervals and durations, or event-triggered burst</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Memory Modes</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Wrap when full or stop when full</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Start Modes</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Immediate, date & time, or next interval</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Stop Modes</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">When memory full, stop with HOBOmobile, date & time, or after a set logging period</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Time Accuracy</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">±1 minute per month 0° to 50°C (32° to 122°F)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Battery</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Two AA, 1.5 V alkaline batteries, user replaceable</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Battery Life</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">1 year, typical with logging interval of 1 minute. Faster logging and/or statistics sampling intervals, entering burst logging mode, excessive readouts, checking of Full Status Details, and remaining connected with HOBOmobile will impact battery life.</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Memory</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">256 KB memory (30,000 sets of measurements)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Full Memory Download Time</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Approximately 2 minutes; may take longer the further the device is from the top end of the logger</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Dimensions</strong><br></td><td><p style="font-family: Arial, sans-serif; color: rgb(0, 0, 0); font-size: 13.333333015441895px;">Top end (MX2001-TOP): 2.54 cm (1.0 inches) diameter, 28.9 cm (11.4 inches) length; mounting hole 7.6 mm (0.3 inches) diameter</p><p style="font-family: Arial, sans-serif; color: rgb(0, 0, 0); font-size: 13.333333015441895px;">Sensor end (MX2001-0x-S and MX2001-0x-Ti-S: 2.54 cm (1.0 inches) diameter, 9.91 cm (3.9 inches) length</p><p style="font-family: Arial, sans-serif; color: rgb(0, 0, 0); font-size: 13.333333015441895px;"><strong>Note:</strong> The length of the water level logger cable (CABLE-DR-xxx) can vary -0% to +3% +10 cm (3.9 inches) from the length ordered. The logger adds 38.8 cm (15.3 inches) to the length of the cable ordered. </p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Weight</strong><br></td><td><p style="font-family: Arial, sans-serif; color: rgb(0, 0, 0); font-size: 13.333333015441895px;">Top end (MX2001-TOP): Approximately 136 g (4.78 oz) in air</p><p style="font-family: Arial, sans-serif; color: rgb(0, 0, 0); font-size: 13.333333015441895px;">Stainless sensor end (MX2001-0x-S): Approximately 106 g (3.74 oz) in air; approximately 53.9 g (1.9 oz) in fresh water</p><p style="font-family: Arial, sans-serif; color: rgb(0, 0, 0); font-size: 13.333333015441895px;">Titanium sensor end (MX2001-0x-Ti-S): Approximately 80 g (2.83 oz) in air; approximately 37 g (1.3 oz) in fresh water</p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Wetted Materials</strong><br></td><td><p style="font-family: Arial, sans-serif; color: rgb(0, 0, 0); font-size: 13.333333015441895px;">Top end (MX2001-TOP): Acetal housing, Polycarbonate end caps, Polycarbonate collar nut; Viton and Buna-N O-rings</p><p style="font-family: Arial, sans-serif; color: rgb(0, 0, 0); font-size: 13.333333015441895px;">Stainless sensor end (MX2001-0x-S): Acetal housing, PVC end cap, Polycarbonate collar nut; Viton and Buna-N O-rings; ceramic sensor in stainless steel end cap</p><p style="font-family: Arial, sans-serif; color: rgb(0, 0, 0); font-size: 13.333333015441895px;">Titanium sensor end (MX2001-0x-Ti-S): Acetal housing, PVC end cap, Polycarbonate collar nut; Viton and Buna-N O-rings; ceramic sensor in Titanium end cap</p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Environmental Rating</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">NEMA 6, IP67 (top end)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Certifications</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).</span><br></td></tr></tbody></table><p><br></p> |
Pressure (Absolute) and Water Level Sensor MX2001 - 30 Meters | <p><br></p><table class="table table-bordered"><tbody><tr><td><span style="font-weight: bold; background-color: rgb(255, 255, 255); color: rgb(0, 0, 0);">Operation range</span></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m of water depth at sea level, or 0 to 33.6 m of water at 3,000 m (10,000 ft) of altitude</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Factory Calibrated Range</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">69 to 400 kPa (10 to 58 psia), 0° to 40°C (32° to 104°F)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Burst Pressure</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">500 kPa (72.5 psia) or 40.8 m (60 ft) depth</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Water Level Accuracy*</strong><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Typical error: ±0.05% FS, 1.5 cm (0.015 ft) water</span><br style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Maximum error: ±0.1% FS, 3.0 cm (0.03 ft) water</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">*</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Water Level Accuracy: With accurate reference water level measurement, known water density, and a stable temperature environment. System Water Level Accuracy equals the sum of the Barometric Water Level Accuracy plus the selected sensor end Water Level Accuracy.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span><br></p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Raw Pressure Accuracy**</strong><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">±0.3% FS, 1.20 kPa (0.17 psi) maximum error</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">**Raw Pressure Accuracy: Absolute pressure sensor accuracy includes all sensor drift, temperature, and hysteresis-induced errors.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span></p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Resolution</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><0.04 kPa (0.003 psi), 0.41 cm (0.007 ft) water</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Pressure </strong><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Response Time (90%)***</span><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">1 second at a stable temperature</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">*</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">**Changes in Temperature: Allow 20 minutes in water to achieve full temperature compensation of the pressure sensor. There can be up to 0.5% of additional error due to rapid temperature changes. Measurement accuracy also depends on temperature response time.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span><br></p></td></tr></tbody></table><p><br></p><p><br></p> |
Pressure (Absolute) and Water Level Sensor MX2001 - 4 Meters | <p><br></p><table class="table table-bordered"><tbody><tr><td><span style="font-weight: bold; background-color: rgb(255, 255, 255); color: rgb(0, 0, 0);">Operation range</span></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m (0 to 23 ft) of water at 3,000 m (10,000 ft) of altitude</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Factory Calibrated Range</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">69 to 145 kPa (10 to 21 psia), 0° to 40°C (32° to 104°F)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Burst Pressure</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">310 kPa (45 psia) or 18 m (60 ft) depth</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Water Level Accuracy*</strong><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Typical error: ±0.05% FS, 0.3 cm (0.01 ft) water</span><br style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Maximum error: ±0.1% FS, 0,6 cm (0.02 ft) water</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">*</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Water Level Accuracy: With accurate reference water level measurement, known water density, and a stable temperature environment. System Water Level Accuracy equals the sum of the Barometric Water Level Accuracy plus the selected sensor end Water Level Accuracy.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span><br></p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Raw Pressure Accuracy**</strong><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">±0.3% FS, 0.43 kPa (0.063 psi) maximum error</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">**Raw Pressure Accuracy: Absolute pressure sensor accuracy includes all sensor drift, temperature, and hysteresis-induced errors.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span></p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Resolution</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><0.014 kPa (0.003 psi), 0.14 cm (0.007 ft) water</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Pressure </strong><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Response Time (90%)***</span><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">1 second at a stable temperature</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">*</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">**Changes in Temperature: Allow 20 minutes in water to achieve full temperature compensation of the pressure sensor. There can be up to 0.5% of additional error due to rapid temperature changes. Measurement accuracy also depends on temperature response time.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span><br></p></td></tr></tbody></table><p><br></p> |
Pressure (Absolute) and Water Level Sensor MX2001 - 76 Meters | <p><br></p><table class="table table-bordered"><tbody><tr><td><span style="font-weight: bold; background-color: rgb(255, 255, 255); color: rgb(0, 0, 0);">Operation range</span></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">0 to 850 kPa (0 to 123,3 psia); approximately 0 to 76.5 m of water depth at sea level, or 0 to 79.5 m of water at 3,000 m (10,000 ft) of altitude</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Factory Calibrated Range</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">69 to 850 kPa (10 to 123,3 psia), 0° to 40°C (32° to 104°F)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Burst Pressure</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">1200 kPa (174 psia) or 112 m (368 ft) depth</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Water Level Accuracy*</strong><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Typical error: ±0.05% FS, 3.8 cm (0.125 ft) water</span><br style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Maximum error: ±0.1% FS, 7.6 cm (0.25 ft) water</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">*</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Water Level Accuracy: With accurate reference water level measurement, known water density, and a stable temperature environment. System Water Level Accuracy equals the sum of the Barometric Water Level Accuracy plus the selected sensor end Water Level Accuracy.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span><br></p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Raw Pressure Accuracy**</strong><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">±0.3% FS, 2.55 kPa (0.37 psi) maximum error</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">**Raw Pressure Accuracy: Absolute pressure sensor accuracy includes all sensor drift, temperature, and hysteresis-induced errors.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span></p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Resolution</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><0.085 kPa (0.012 psi), 0.87 cm (0.028 ft) water</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Pressure </strong><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Response Time (90%)***</span><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">1 second at a stable temperature</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">*</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">**Changes in Temperature: Allow 20 minutes in water to achieve full temperature compensation of the pressure sensor. There can be up to 0.5% of additional error due to rapid temperature changes. Measurement accuracy also depends on temperature response time.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span><br></p></td></tr></tbody></table><p><br></p> |
Pressure (Absolute) and Water Level Sensor MX2001 - 9 Meters | <p><br></p><table class="table table-bordered"><tbody><tr><td><span style="font-weight: bold; background-color: rgb(255, 255, 255); color: rgb(0, 0, 0);">Operation range</span></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Factory Calibrated Range</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">69 to 207 kPa (10 to 30 psia), 0° to 40°C (32° to 104°F)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Burst Pressure</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">310 kPa (45 psia) or 18 m (60 ft) depth</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Water Level Accuracy*</strong><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Typical error: ±0.05% FS, 0.5 cm (0.015 ft) water</span><br style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Maximum error: ±0.1% FS, 1.0 cm (0.03 ft) water</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">*</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Water Level Accuracy: With accurate reference water level measurement, known water density, and a stable temperature environment. System Water Level Accuracy equals the sum of the Barometric Water Level Accuracy plus the selected sensor end Water Level Accuracy.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span><br></p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Raw Pressure Accuracy**</strong><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">±0.3% FS, 0.62 kPa (0.09 psi) maximum error</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">**Raw Pressure Accuracy: Absolute pressure sensor accuracy includes all sensor drift, temperature, and hysteresis-induced errors.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span></p></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Resolution</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Pressure </strong><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Response Time (90%)***</span><br></td><td><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">1 second at a stable temperature</span></p><p><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">*</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">**Changes in Temperature: Allow 20 minutes in water to achieve full temperature compensation of the pressure sensor. There can be up to 0.5% of additional error due to rapid temperature changes. Measurement accuracy also depends on temperature response time.</span><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;"><br></span><br></p></td></tr></tbody></table><p><br></p><p><br></p> |
Temperature Measurements (All Sensor End Models) | <p><br></p><table class="table table-bordered"><tbody><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Operation Range</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">-20° to 50°C (-4° to 122°F)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Accuracy</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">±0.44°C from 0° to 50°C (±0.79°F from 32° to 122°F), see Plot A</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Resolution</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">0.1°C at 25°C (0.18°F at 77°F), see Plot A in manual</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Response Time (90%</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">5 minutes in water (typical)</span><br></td></tr><tr><td><strong style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">Stability (Drift)</strong><br></td><td><span style="color: rgb(0, 0, 0); font-family: Arial, sans-serif; font-size: 13.333333015441895px;">0.1°C (0.18°F) per year</span><br></td></tr></tbody></table><p><br></p> |