Aqua TROLL 600 Multiparameter Sonde










- Model: Aqua TROLL 600
- Weight: 1.45kg
- Dimensions: 60.20cm x4.70cm x4.70cm
- MPN: AT600
The Aqua TROLL 600 is a customizable, powerful multiparameter sonde. It combines industry-leading water quality sensors with revolutionary smartphone mobility, allowing you the ability to collect and analyze data using the VuSitu Mobile App on your Android™ device. Rugged in groundwater and corrosion-resistant in surface water, the Aqua TROLL 600 delivers accurate data in an easy-to-use, customizable instrument. Features include a quick-read LCD status screen for visual indicators of overall readiness, battery life, internal log, and sensor status, as well as integrated Bluetooth® connection for wireless data access, and an onboard micro SD card for data backup and download.
Low power consumption with 9+ months of battery life, and advanced antifouling to protect all sensors, make it perfect for challenging environments and long-term deployments in fresh and salt water applications. The Aqua TROLL 600 features self-compensating turbidity, optical RDO, and level, and comes in vented and non-vented options. It is the only multiparameter sonde to have a sub-2 inch passive and active antifouling system for all sensors, including conductivity. Every detail has been engineered for maximum accuracy and minimum hassle. This flexible, data-ready sonde easily integrates with telemetry systems and our new HydroVu Data Services platform for real-time feedback on all your remote water monitoring sites. Access to your data has never been this easy.
Features:
- Base sensor configuration includes EPA-approved optical RDO, pH/ORP, turbidity, conductivity, temperature, and pressure
- Ammonium, chloride and nitrate ISE nutrient sensors available
- Sub-2 inch passive and active antifouling system for all sensors, including cleanable conductivity
- Vented (gauged) or non-vented (absolute) pressure measurement
- Wireless Bluetooth® connection to the VuSitu Mobile App for Android or Win-Situ 5 for PC/laptop
- Site tagging, GPS coordinates, and auto-calibration functions through the VuSitu Mobile App
- LCD display for visual indication of overall probe functionality and battery, sensor, and log status
- Internal memory plus an integrated micro SD card for data backup and download
- RuggedCable options in poly or Tefzel for use in harsh environments
- Field-tested design with corrosion-resistant housing
- NIST calibration report for guaranteed accuracy
- Dual-sided restrictor acts as a storage cup between deployments
- Compatible with low-flow system (sold separately)
Benefits:
- Customize to your needs – Flexible instrument that can be configured and modified based on the unique requirements of each site. Wet-mateable connectors and universal ports allow you to change sensors on the fly, so you can monitor the parameters you need for each job.
- Minimal maintenance and field time – Drift-resistant sensors, long-lasting battery power, and corrosion-resistant design support long-deployments. Active and passive antifouling systems reduce cleaning requirements and extend the life of your investment. Reliable data logging and plenty of memory mean less trips to the field.
- Get more accurate data — High-accuracy sensors come factory calibrated to give you the most reliable data possible. Smart sensors store information internally, maintaining data and calibration within the sensor for traceable results.
- Quick and easy data-sharing – Sonde gives you real-time data access and instant results that can be emailed on the spot using your mobile device. Intuitive VuSitu Mobile App is an all-in-one software package that provides auto-configuration, simplified calibration, directed data analysis, and automated report creation.
- Get built-in support — access free, 24/7 tech support right from the mobile app.
Includes:
- Aqua TROLL 600 Multiparameter Sonde, custom configured for your application
- Sensors available: temperature, conductivity/temperature, turbidity, optical RDO, pH/ORP, vented or non-vented level
- Two Alkaline D batteries
- Micro SD card
- Sensor installation tools
- Maintenance supplies
- Win-Situ 5 Software, User Manual, and Quick Start Guide
- NIST Calibration Report
In order to get the most accurate readings possible with your Aqua TROLL 600, we recommend the following calibration procedure.
Specifications | |
General | <table class="table table-bordered"><tbody><tr><td><span style="font-weight: bold;">Operating Temperature (nonfreezing)<br></span></td><td>-5 to 50° C (23 to 122° F)<br>ISE: Ammonium & Nitrate 0 to 40° C ; Chloride 0 to 50° C<br></td></tr><tr><td><span style="font-weight: bold;">Storage Temperature</span><br></td><td>Components w/o fluid: -40° C to 65° C (non-freezing water);<br>pH/ORP: -5° C to 65° C;<br>Ammonium/Nitrate: 0 to 40 ° C;<br>Chloride: 0 to 50° C<br></td></tr><tr><td><span style="font-weight: bold;">Dimensions</span><br></td><td>4.7 cm (1.85 in.) OD x 60.2 cm (23.7 in.) (includes connector)<br>With bail: 72.9 cm (28.7 in.) <br></td></tr><tr><td><span style="font-weight: bold;">Weight</span><br></td><td>1.45 kg / 3.2 lbs (includes all sensors, batteries, and bail)<br></td></tr><tr><td><span style="font-weight: bold;">Wetted Materials</span><br></td><td>PC, PC alloy, Delrin™, Santoprene™, Inconel™, Viton™, Titanium, Platinum, Ceramic, Nylon<br></td></tr><tr><td><span style="font-weight: bold;">Environmental Rating</span><br></td><td>IP68 with all sensors and cable attached<br>IP67 without the sensors, battery cover or cable attached<br></td></tr><tr><td><span style="font-weight: bold;">Max Pressure Rating</span><br></td><td>Up to 350 PSI<br></td></tr><tr><td><span style="font-weight: bold;">Output Options</span><br></td><td>RS-485/MODBUS, SDI-12, Bluetooth® <br></td></tr><tr><td><span style="font-weight: bold;">Internal Memory Micro SD Card</span><br></td><td>16 MB; 8+ GB micro SD card included, user replaceable<br></td></tr><tr><td><span style="font-weight: bold;">Internal Power Battery Life</span> <br></td><td>2 internal user-replaceable Alkaline D batteries<br>>6 months typical with wiping<br>>9 months typical with no wiping<br></td></tr><tr><td><span style="font-weight: bold;">External Power Voltage</span><br></td><td>8-36 VDC (not required for normal operation)<br></td></tr><tr><td><span style="font-weight: bold;">External Power Current</span><br></td><td>Sleep: 0.10 mA typical<br>Measurement: 16 mA typical, 45 mA max<br></td></tr><tr><td><span style="font-weight: bold;">Reading Rates</span><br></td><td>1 reading every 2 seconds<br></td></tr><tr><td><span style="font-weight: bold;">Data Logging</span><br></td><td>50 logs (defined, scheduled to run, or stored)<br></td></tr><tr><td><span style="font-weight: bold;">Logging Modes</span><br></td><td>Linear, Linear Average, Event<br></td></tr><tr><td><span style="font-weight: bold;">Logging Rate</span><br></td><td>1 minute to 99 hours<br></td></tr><tr><td><span style="font-weight: bold;">Hex Screw Driver</span><br></td><td>0.050, 1.3 mm<br></td></tr><tr><td><span style="font-weight: bold;">Communication Device</span><br></td><td>TROLL Com or Wireless TROLL Com<br></td></tr><tr><td><span style="font-weight: bold;">Cable Options</span><br></td><td>Vented or non-vented polyurethane or vented Tefzel®<br></td></tr><tr><td><span style="font-weight: bold;">LCD Display</span><br></td><td>Integrated display shows status of sonde, sensor ports, data log, battery and connectivity.<br></td></tr><tr><td><span style="font-weight: bold;">Software</span><br></td><td>Android™: VuSitu through Google Play™, Windows®: Win-Situ 5, Data Services: HydroVu<br></td></tr><tr><td><span style="font-weight: bold;">Interface</span><br></td><td>Android 4.4, requires Bluetooth 2.0;<br>Win-Situ 5 Software<br></td></tr><tr><td><span style="font-weight: bold;">Certifications</span><br></td><td>CE, FCC, WEEE, RoHS Compliant<br></td></tr></tbody></table> |
Sensors | <table class="table table-bordered"><tbody><tr><td><br></td><td><span style="color: rgb(115, 165, 173);"><span style="font-weight: bold;">Accuracy</span><br></span></td><td><span style="color: rgb(115, 165, 173);"><span style="font-weight: bold;">Range</span><br></span></td><td><span style="color: rgb(115, 165, 173);"><span style="font-weight: bold;">Resolution/Precision</span><br></span></td><td><span style="color: rgb(115, 165, 173);"><span style="font-weight: bold;">Response Time</span><br></span></td><td><span style="color: rgb(115, 165, 173);"><span style="font-weight: bold;">Units of Measure</span><br></span></td><td><span style="font-weight: bold; color: rgb(115, 165, 173);">Method</span><br></td></tr><tr><td><span style="font-weight: bold;">Temperature</span><br></td><td>± 0.1º C<br></td><td>-5 to 50º C (23 to 122º F)<br></td><td>0.01º C<br></td><td>T63<2s, T90<15s, T95<30s<br></td><td>Celsius or Fahrenheit<br></td><td>EPA 170.1<br></td></tr><tr><td><span style="font-weight: bold;">Barometric Pressure</span><br></td><td>± 1.0 mbars<br></td><td>300 to 1,100 mbar<br></td><td>0.1 mbar<br></td><td>T63<1s, T90<1s, T95<1s<br></td><td>Pressure: psi, kPa, bar, mbar, inHg, mmHg<br></td><td>Silicon strain gauge<br></td></tr><tr><td><span style="font-weight: bold;">pH </span><br></td><td>±0.1 pH unit or better<br></td><td>0 to 14 pH units<br></td><td>0.01 pH<br></td><td>T63<3s, T90<15s, T95<30s<br></td><td>pH, mV<br></td><td>Std. Methods 4500-H+/ EPA 150.2<br></td></tr><tr><td><span style="font-weight: bold;">ORP </span><br></td><td>±5 mV<br></td><td>±1,400 mV<br></td><td>0.1 mV<br></td><td>T63<3s, T90<15s, T95<30s<br></td><td>mV<br></td><td>Std. Methods 2580<br></td></tr><tr><td><span style="font-weight: bold;">Conductivity</span><br></td><td>+/-0.5% of reading plus 1 µS/ cm from 0 to 100,000 µS/cm;<br>+/- 1.0% of reading from 100,000 to 200,000 µS/cm<br></td><td>0 to 350,000 µS/cm<br></td><td>0.1 µS/cm<br></td><td>T63<1s, T90<3s, T95<5s<br></td><td>Actual conductivity (μS/cm, mS/ cm);<br>Specific conductivity (μS/cm, mS/cm);<br>Salinity (PSU);<br>Total dissolved solids (ppt, ppm);<br>Resistivity (Ohms-cm);<br>Density (g/cm3)<br></td><td>Std. Methods 2510/ EPA 120.1<br></td></tr><tr><td><span style="font-weight: bold;">TDS (derived from conductivity and temp)</span><br></td><td>-</td><td>0 to 350 ppt<br></td><td>0.1 ppt<br></td><td>-</td><td>ppt, ppm<br></td><td>-</td></tr><tr><td><span style="font-weight: bold;">Salinity (derived from conductivity and temp)<br></span></td><td>-</td><td>0 to 350 PSU<br></td><td>0.1 PSU<br></td><td>-</td><td>PSU, ppt<br></td><td>Std. Methods 2520A<br></td></tr><tr><td><span style="font-weight: bold;">Rugged Dissolved Oxygen (RDO) with RDO-X<br></span></td><td>±0.1 mg/L<br>±0.2 mg/L<br>±10% of reading<br></td><td>0 to 8 mg/L<br>8 to 20 mg/L<br>20 to 50 mg/L<br></td><td>0.01 mg/L<br></td><td>T63<15s, T90<45s, T95<60s<br></td><td>mg/L, % saturation, ppm<br></td><td>EPA-approved In-Situ Methods: 1002-8-2009, 1003-8-2009, 1004- 8-2009<br></td></tr><tr><td><span style="font-weight: bold;">Turbidity</span><br></td><td>±2% of reading or ±2 NTU, FNU, whichever is greater<br></td><td> 0 to 4,000 NTU<br></td><td>0.01 NTU (0 to 1,000);<br>0.1 NTU (1,000 to 4,000)<br></td><td>T63<1s, T90<1s, T95<1s<br></td><td>NTU, FNU<br></td><td>ISO 7027<br></td></tr><tr><td><span style="font-weight: bold;">TSS (derived from turbidity)<br></span></td><td>-</td><td>0 to 1,500 mg/L<br></td><td>0.1 mg/L<br></td><td>-</td><td>ppt, mg/L<br></td><td>-</td></tr><tr><td><span style="font-weight: bold;">Ammonium (NH4 + - N) Rated to 25m depth<br></span></td><td>±10% or ±2 mg/L w.i.g.<br></td><td>0 to 10,000 mg/L as N<br></td><td>0.01 mg/L<br></td><td>T63<1s, T90<10s, T95<30s<br></td><td>mg/L, ppm, mV<br></td><td>-</td></tr><tr><td><span style="font-weight: bold;">Unionized Ammonia, Total Ammonia (derived from Ammonium & pH sensor)<br></span></td><td><br></td><td>0 to 10,000 mg/L as N<br></td><td>0.01 mg/L<br></td><td>-</td><td>mg/L, ppm<br></td><td>-</td></tr><tr><td><span style="font-weight: bold;">Nitrate (NO3- - N) Rated to 25m depth<br></span></td><td>±10% or ±2 mg/L w.i.g.<br></td><td>0 to 40,000 mg/L as N<br></td><td>0.01 mg/L<br></td><td>T63<1s, T90<1s, T95<1s<br></td><td>mg/L, ppm, mV<br></td><td>Std. Methods 4500 NO3 D<br></td></tr><tr><td><span style="font-weight: bold;">Chloride (Cl)<br></span></td><td>±10% or ±2 mg/L w.i.g.<br></td><td>0 to 150,000 mg/L as Cl<br></td><td>0.01 mg/L<br></td><td>T63<1s, T90<10s, T95<30s<br></td><td>mg/L, ppm, mV<br></td><td>Std. Methods 4500 Cl- D<br></td></tr><tr><td><span style="font-weight: bold;">Pressure (Optional)<br></span></td><td>±0.1% full scale (FS)<br></td><td>Non-Vented or Vented<br>9.0 m (30ft) (Burst: 27 m; 90 ft)<br>30 m (100 ft) (Burst: 40 m; 130 ft)<br>76 m (250 ft) (Burst: 107 m; 350 ft)<br>200 m (650 ft) (Burst: 229 m; 750 ft)<br></td><td>0.01% full scale<br></td><td>T63<1s, T90<1s, T95<1s <br></td><td>Pressure: psi, kPa, bar, mbar, inHg, mmHg<br>Level: in, ft, mm, cm, m, cmH20, inH2O<br></td><td>Piezoresistive; Ceramic<br></td></tr></tbody></table> |